Controls

Hydraulics

GSGR GS15031-102 AL10

Air Cooled, (air-to-oil), Nominal Heat Rejection:  6 HP,  with Filtration & Gauge.

The GS Global Resources GS15031-102 AL10 Offline Cooling System allows for cooling of gearboxes and reservoir solutions without impacting existing plumbing of the system.

• The cooler is a compact system for removing approximately 6 HP of heat continuously from hydraulic or lubrication system.
• A small compact size cooling solution allows for installation in tight areas and is ready to install
• The compact solution utilizes proven air cooler cores allowing for cooling of thick lube oils
• The system comes with thermal bypass valve and is protected from over pressure
• The 3 phase multi voltage premium efficient dual shafted motor is rated for out door use which allows the cooling system to be installed in most applications
• The double shafted motor solution with gear pump allows for pumping of fluids from ISO150 to ISO320
• Gear pump has double shaft seal for pumping of very thick fluid
• The pump is designed for high vacuum inlet condition
• The system has a 25-micron filter for cleaning the oil while cooling
• A bypass valve allows for element replacement while the system is running with no interruption
• System options include higher performance filter elements and advanced switch for dirty filter alarm as well
• All cooler systems can be customized to meet your needs

  • + expand all
  • - collapse all

Specifications

Mechanical

Electric Motor Information - -
2.0 HP at 60 Hz (208, 230, and 460V 3 phase) 1170RPM Amps (8.0, 7.2, and 3.6)
1.5 Hp at 50 Hz (190-200/380-400V 3 phase) 960 RPM Amps (13.0, 12.0, 6.5, 6.0)
- -
Envelope Dimension L. 38.0 X W. 24.0 X H. 24.3 inches -
- -
Porting - -
Inlet - #20JIC male 37° -
Outlet - #16 JIC male 37° -
- -
Gear Pump - -
Flow @ 60Hz- 7.6 GPM -
Flow @ 50Hz- 6.2 GPM -
Notes Double shaft seal for high viscosity oils is critical in ensuring proper performance. Larger suction port allows for very high viscosity pumping when oil is cold and high viscosity -

Heat Rejection

(HP)/BTU/Hour @50°F Delta Temp (6.14 HP) 15,620 BTU/Hr. @ 60 Hz -
(6.00 HP) 15,320 BTU/Hr. @ 50 Hz -

Temperature

Control and Bypass Temp control - full bypass below 140°F, transition from 140°F to 165°F, no bypass after 165°F -
Relief Pressure 65 PSID relief for cooler safety -

General

Filtration - -
Schroeder Industries KF3 Filter 25 micron with Delta-P gauge Optional elements of 3, 5, 10 micron, also micro glass media
3-way ball valve for service of filter -
- -
Electric motors are totally enclosed non ventilated (TENV) double shafted units. The motors are premium efficient with multiple voltage ratings. All motors are three phase -

Applications:

Industrial - -

Resources

Can't find what you are looking for or need more information? Contact us