Controls

Hydraulics

Eaton FAZ-NA UL 489 Industrial Miniature Circuit Breakers

Eaton offers a full range of DIN-Rail miniature circuit breakers up to 40A current rating for feeder and branch circuit protection.

Breakers comply with the latest national and international standards including UL 489. Two levels of circuit protection available, one for medium inrush startup currents to provide protection for small transformers, pilot devices, etc., and one with a magnetic range to allow for higher inrush levels during startup usually seen with motors.

Optimum product quality, tested reliability and safety stand for the best protection of personnel, installations and plant. Eaton’s FAZ-NA DIN rail mountable circuit breakers are designed for use in branch service applications.

  • + expand all
  • - collapse all

Specifications

Electrical

UL 489 Circuit Breakers - -
Used for branch circuit protection, internal/external receptacles, external motors and HACR equipment (heating, air conditioning and refrigeration) -
'Single-, two- and three-pole breakers -
Up to 14 kAIC at 277/480V -
Fulfills both UL 489 and UL 1077 -
DIN rail mounted -
B, C and D curves -
IEC 60947-2 -

General

Features: - -
Current limiting design provides fast short-circuit interruption that reduces the let-through energy that can damage the circuit -
Thermal-magnetic overcurrent protection -
Three levels of short-circuit protection, Categorized by B, C and D curves -
Trip-free design. Breaker can not be defeated by holding the handle in the ON position -
A color-coded red/green indicator provides immediate visual indication of device status (green for OFF, red for ON) and isolation function -
Power to the circuit breakers can be fed from the line or load side -
Separate version for ring-tongue connection (Type FAZ-RT), terminal screws can be removed (on both sides). Captive screws cannot be lost -
Fulfill UL 489, CSA C22.2 No.5 and also IEC 60947-2 Standard. For use in applications for which UL 1077 or CSA C22.2 No.235 are also allowed -
Easy installation on DIN rail. Module width of only 17.7 mm (per pole) -
To save installation time, bus-connectors and feeder terminal facilitate mounting and wiring of multiple miniature circuit breaker arrays in control panel assemblies -

Other

Options: - -
Auxiliary contact -
Bus-bar -
Bus-connector -
Extension terminal: standard box or ring tung -
Padlock hasp -
Shunt trip -
- -
Application: - -
Feeder and branch circuit protection for: -
Convenience receptacle circuits (internal/external) -
Motor control circuits -
Load circuits leaving the equipment (external) -
HACR equipment (heating, air conditioning, refrigeration) -
PLC I/O points -
Computers -
Power supplies -
Control instrumentation -
Relays -
UPS -
Power conditioners -

Resources